Frida TD
Integrated tan delta measuring capability - No additional external hardware required
Frida TD Features
- VLF voltages up to 24 kVRMS (34 kV peak) and DC voltages up to 34 kV
- VLF cable testing and tan delta diagnostics in one device
- Easy and quick test setup with integrated high voltage cable
- Automatic testing and tan delta diagnostics or monitored withstand testing according to IEEE 400.2
- Easy custom programming of testing and diagnostic sequences
- Based on the measurement results and limit values, the recommendation system suggests an optimal test duration
- Top tan delta precision (1x10-4)
- Immediate tan delta signaling during the test: OK | CRITICAL | BAD
- USB data transfer and display of measurement data with BAUR Diagnostic Reporter
- Ideal for complete cable diagnostic testing of 20 kV cable systems
- Ideal for maintenance testing of 25 kV cable systems
Parallel TD and PD diagnostics possible in combination with PD-TaD 62