CDN3000A-06-32:  Three Phase Power Line Application (690VAC and 32A per phase)

Conducted Immunity CDN3000A-06-32 Test Setup

The CDN3000A-06-32 is a fully automatic coupling decoupling network controlled by the IMU Series or TRA Series of transient generators.  The CDN3000A-06-32 is used to couple EFT/Burst (IEC 61000-4-4), Surge Combination Wave (IEC 61000-4-5), and Ring Wave (IEC 61000-4-12) on to three phase power lines up to 690VAC and 32A per phase.  The CDN3000A-06-32 has a built in circuit breaker to provide over current protection to the user, EUT and transient generator.

PICTURE NEEDED

The CDN3000A-06-63 is a fully automatic coupling decoupling network controlled by the IMU Series or TRA Series of transient generators.  The CDN3000A-06-63  is used to couple EFT/Burst (IEC 61000-4-4), and Surge Combination Wave on to three phase power lines up to 690VAC and 63A per phase.  The CDN3000A-06-63 has a built in circuit breaker to provide over current protection to the user, EUT and transient generator.


CDN-A-P100-690:  Three Phase Power Line Application (690VAC and 100A per phase)

Conducted Immunity CDN-A-P100-690 F S

The CDN-A-P100-690 is a fully automatic coupling decoupling network controlled by the IMU Series or TRA Series of transient generators.  The CDN-A-P100-690  is used to couple EFT/Burst (IEC 61000-4-4), and Surge Combination Wave (IEC 61000-4-5) on to three phase power lines up to 690VAC and 100A per phase.  The CDN-A-P100-690 has a built in circuit breaker to provide over current protection to the user, EUT and transient generator.


CDN-A-3P200-690 F-S:  Three Phase Power Line Application (690VAC and 200A per phase)

CDN-A-3P200-690 F S Test Setup

The CDN-A-3P200-690 F-S is a fully automatic coupling decoupling network controlled by the IMU Series or TRA Series of transient generators.  The CDN-A-3P200-690 F-S  is used to couple EFT/Burst (IEC 61000-4-4), and Surge Combination Wave (IEC 61000-4-5) on to three phase power lines up to 690VAC and 200A per phase.  The CDN-A-3P200-690 F-S has a built in circuit breaker to provide over current protection to the user, EUT and transient generator.


CDN-A-3P100-AC-DC: AC and DC CDN up to 1000V DC / 100A and 690VAC / 100A

Conducted Immunity CDN-A-3P100-AC-DC Test Setup

The CDN-A-3P100-AC-DC is an automatic CDN specifically designed for Inverter and Solar testing applications.  This CDN is capable of inducing EFT/Burst (IEC 61000-4-4) and Surge Combination Wave (IEC 61000-4-5) on to 1000V DC / 100A and 690VAC / 100A lines.  This CDN can be used to test the AC side and the DC side for solar applications.  The CDN-A-3P100-AC-DC has a built in circuit breaker to provide over current protection to the user, EUT and transient generator.

 